Switchgear
Switchgear
Switchgear
Switchgear Switchgear
Switchgear Switchgear
Switchgear Switchgear
Switchgear
Main products include MNS, GCS, GCK, GGD, KYN28a, KYN and other high and low voltage distribution cabinet cabinets and complete equipment.
  • Specification & Series:GCS low voltage draw out complete switchgear
    XGN2-12 box fixed AC metal enclosed switchgear
    GCK low voltage draw out switchgear
SERVICE CALL+86 13521339794
Price Inquiry
Online Remarks
enfi.cemsa@gmail.com
Advantages & Features
Working Principle
GCK low voltage draw out switch cabinet: applicable to power plants, substations, industrial and mining enterprises and other power users as the power system with AC 50Hz, maximum working voltage up to 660V and maximum working current up to 4000A. It is used for power distribution, motor control and other power distribution equipment for power conversion and distribution control.
GCS low voltage draw out switchgear: suitable for power distribution system in power plant, petroleum, metallurgy, textile, chemical industry, high-rise building and other industries. In large power plants, petrochemical systems and other places with high degree of automation and requiring computer interface, it is used as a complete set of low-voltage power distribution devices for power generation and supply systems with three-phase AC frequency of 50Hz, rated working voltage of 400V and rated current of 4000A and below, power distribution in motor system, centralized control of electric machines and reactive power compensation.
Xgn2-12 box type: it is suitable for receiving and distributing electric energy in the power system with rated voltage of 3.6 ~ 12kV, three-phase AC 50Hz and rated circuit of 630 ~ 4000A. It is especially suitable for frequent operation.
Technical Parameters
GCS Technical parametersⅠ GCK Technical parametersⅡ XGN2 Technical parametersⅢ
Rated voltage of
main circuit (V)
Communication 380 (400),660 Rated insulation voltage (V) 660 Project
Rated voltage of
auxiliary circuit (V)
AC 220, 380 (400) DC 110,220 Rated working voltage
of main circuit (V)
380 Rated voltage(kV) 3;6;10
Rated frequency (Hz) 50(60) Rated working voltage
of auxiliary circuit (V)
AC380.220;DC220.110 Maximum operating voltage(kV) 3.6;7.6;12
Rated insulation voltage (V) 660(1000) Rated frequency (Hz) 50 Rated current(A) 5~2500
Rated current (a)
Horizontal bus
≤4000 Rated working current (a) 630、1000,1600、
2000.2500.3000
Rated short-circuit
breaking current(kV)
16;20;31.5;40
Rated current (a)
Vertical bus (MCC)
1000 Rated short-time
withstand current (KA)
50/30.30 (neutral bus) Rated short circuit
closing current(kV)
40;50;80;100
Rated short-time withstand
current of bus (ka/1s)
50、80 Rated peak
withstand current (KA)
63.105 Rated dynamic
stable current(kV)
40;50;80;100
Rated peak withstand current
of bus (Ka/0.1s)
105、176 Functional unit (drawer)
breaking capacity (KA) 50
(effective value)
Functional unit (drawer)
breaking capacity (KA) 50
(effective value)
Rated thermal
stability current(kV)
16;20;31.5;40
Power frequency test voltage (V/1min)
Main circuit
2500 Motor capacity range (kw) 0.45- 160 Rated thermal
stability time(s)
4
Power frequency test voltage (V/1min)
Auxiliary circuit
2360 Dielectric strength (v/1min) 2500 Protection level IP2X
A bus or bus bar
Three phase four wire system
A、B、C、NPE Enclosure protection level IP30 Bus system Single bus
A bus or bus bar
Three phase five wire system
A、B、C、N、PE Bus setting Three phase four wire system
Three phase five wire system
Operation mode Electromagnetic type
Spring energy storage type
Protection level IP40 Operation mode Manual, Electric Overall dimension (W×D×H) mm 1100×1200×2300 (below 1000A)